cl-logic results collected by cl-test-grid

Results on the last two Quicklisp distributions

 quicklisp 2022-04-01quicklisp 2022-07-08
abcl-1.6.0-fasl43-linux-x86
(LOAD cl-logic FAIL) COMMON-LISP:READER-ERROR : The package "SB-INTROSPECT" can't be found.
abcl-1.7.0-fasl43-linux-x86
(LOAD cl-logic FAIL) COMMON-LISP:READER-ERROR : The package "SB-INTROSPECT" can't be found.
abcl-1.7.1-fasl43-linux-x86
(LOAD cl-logic FAIL) COMMON-LISP:READER-ERROR : The package "SB-INTROSPECT" can't be found.
abcl-1.8.0-fasl43-linux-x64
(LOAD cl-logic FAIL) COMMON-LISP:READER-ERROR : The package "SB-INTROSPECT" can't be found.
(LOAD cl-logic FAIL) COMMON-LISP:READER-ERROR : The package "SB-INTROSPECT" can't be found.
abcl-1.8.0-fasl43-linux-x86
(LOAD cl-logic FAIL) COMMON-LISP:READER-ERROR : The package "SB-INTROSPECT" can't be found.
acl-10.0-linux-x86
(LOAD cl-logic FAIL) COMMON-LISP:READER-ERROR : Package "SB-INTROSPECT" not found. [file position = 547]
acl-10.0m-linux-x86
(LOAD cl-logic FAIL) common-lisp:reader-error : Package "sb-introspect" not found. [file position = 547]
acl-10.0ms-linux-x86
(LOAD cl-logic FAIL) common-lisp:reader-error : Package "sb-introspect" not found. [file position = 547]
acl-10.0s-linux-x86
(LOAD cl-logic FAIL) COMMON-LISP:READER-ERROR : Package "SB-INTROSPECT" not found. [file position = 547]
acl-10.1-linux-x86
(LOAD cl-logic FAIL) COMMON-LISP:READER-ERROR : Package "SB-INTROSPECT" not found. [file position = 547]
acl-10.1m-linux-x86
(LOAD cl-logic FAIL) common-lisp:reader-error : Package "sb-introspect" not found. [file position = 547]
acl-10.1ms-linux-x86
(LOAD cl-logic FAIL) common-lisp:reader-error : Package "sb-introspect" not found. [file position = 547]
acl-10.1s-linux-x86
(LOAD cl-logic FAIL) COMMON-LISP:READER-ERROR : Package "SB-INTROSPECT" not found. [file position = 547]
ccl-1.10-r16196-f96-linux-x86
(LOAD cl-logic FAIL) CCL::NO-SUCH-PACKAGE : There is no package named "SB-INTROSPECT" .
ccl-1.11-5-rv1.11.5-f96-linux-x86
(LOAD cl-logic FAIL) CCL::NO-SUCH-PACKAGE : There is no package named "SB-INTROSPECT" .
ccl-1.12-1-f98-linux-x64
(LOAD cl-logic FAIL) CCL::NO-SUCH-PACKAGE : There is no package named "SB-INTROSPECT" .
(LOAD cl-logic FAIL) CCL::NO-SUCH-PACKAGE : There is no package named "SB-INTROSPECT" .
ccl-1.12-1-rv1.12.1-f98-linux-x64
(LOAD cl-logic FAIL) CCL::NO-SUCH-PACKAGE : There is no package named "SB-INTROSPECT" .
clisp-2.49.92-unix-x64
(LOAD cl-logic FAIL) SYSTEM::SIMPLE-PACKAGE-ERROR : READ from #<INPUT BUFFERED FILE-STREAM CHARACTER #P"/home/cl/tg-work-dir/agent/quicklisp/dists/quicklisp/software/cl-logic-20141217-git/shortcuts.lisp" @17>: there is no package with name "SB-INTROSPECT"
(LOAD cl-logic FAIL) SYSTEM::SIMPLE-PACKAGE-ERROR : READ from #<INPUT BUFFERED FILE-STREAM CHARACTER #P"/home/cl/tg-work-dir/agent/quicklisp/dists/quicklisp/software/cl-logic-20141217-git/shortcuts.lisp" @17>: there is no package with name "SB-INTROSPECT"
clisp-2.49.92-unix-x86-asdf3
(LOAD cl-logic FAIL) SYSTEM::SIMPLE-PACKAGE-ERROR : READ from #<INPUT BUFFERED FILE-STREAM CHARACTER #P"/home/testgrid/cl-test-grid/work-dir/agent/quicklisp/dists/quicklisp/software/cl-logic-20141217-git/shortcuts.lisp" @17>: there is no package with name "SB-INTROSPECT"
cmu-snapshot-2014-01__20e_unicode_-linux-x86
(LOAD cl-logic FAIL) C::COMPILER-READ-ERROR : Read error at 567: "(length (sb-introspect:function-lambda-list/\ function)))" Reader error at 580 on #<Stream for file "/home/testgrid/cl-test-grid/work-dir/agent/quicklisp/dists/quicklisp/software/cl-logic-20141217-git/shortcuts.lisp">: package "SB-INTROSPECT" not found
cmu-snapshot-2014-05-dirty__20e_unicode_-linux-x86
(LOAD cl-logic FAIL) C::COMPILER-READ-ERROR : Read error at 567: "(length (sb-introspect:function-lambda-list/\ function)))" Reader error at 580 on #<Stream for file "/home/testgrid/cl-test-grid/work-dir/agent/quicklisp/dists/quicklisp/software/cl-logic-20141217-git/shortcuts.lisp">: package "SB-INTROSPECT" not found
cmu-snapshot-2014-12___20f_unicode_-linux-x86
(LOAD cl-logic FAIL) C::COMPILER-READ-ERROR : Read error at 567: "(length (sb-introspect:function-lambda-list/\ function)))" Reader error at 580 on #<Stream for file "/home/testgrid/cl-test-grid/work-dir/agent/quicklisp/dists/quicklisp/software/cl-logic-20141217-git/shortcuts.lisp">: package "SB-INTROSPECT" not found
cmu-snapshot-2016-12__21b_unicode_-linux-x86
(LOAD cl-logic FAIL) C::COMPILER-READ-ERROR : Read error at 567: "(length (sb-introspect:function-lambda-list/\ function)))" Reader error at 580 on #<Stream for file "/home/testgrid/cl-test-grid/work-dir/agent/quicklisp/dists/quicklisp/software/cl-logic-20141217-git/shortcuts.lisp">: package "SB-INTROSPECT" not found
ecl-16.1.2-unknown-linux-x86-bytecode
(LOAD cl-logic FAIL) COMMON-LISP:SIMPLE-ERROR : There is no package with the name SB-INTROSPECT.
ecl-16.1.2-unknown-linux-x86-lisp-to-c
(LOAD cl-logic FAIL) UIOP/LISP-BUILD:COMPILE-FILE-ERROR : COMPILE-FILE-ERROR while compiling #<cl-source-file "cl-logic" "shortcuts">
sbcl-1.1.11-linux-x86
sbcl-1.1.16-linux-x86
sbcl-1.2.6-linux-x86
sbcl-1.3.12-linux-x86
sbcl-1.3.17-linux-x86
sbcl-1.3.20-linux-x86
sbcl-1.3.21-linux-x86
sbcl-2.2.1-linux-x64

Breakdown by testcases: for every failed testcase the lisp implmentations it fails on

The library does not have a testsuite adapter for CL Test Grid.

To reports overview

Generated at: 2022-07-26 12:39:09 GMT.